Data Center Raised Floor Standard Height

Racks data center seismic control raised floor plinth.
Data center raised floor standard height. 200 500 square meters about 400 mm. If you can t get at least an 18 inch floor height you re going to significantly limit how much wattage you can put in a cabinet. A raised floor also raised flooring access floor ing or raised access computer floor provides an elevated structural floor above a solid substrate often a concrete slab to create a hidden void for the passage of mechanical and electrical services. Typical heights are 24 48 but this is based upon several factors not least of which is the type of air handler fan centrifugal vs.
Tia 942 extends the tia 606 a administration standard to data centers which specifies a labeling scheme for all racks cabinets patch panels patch cords and cables. For example if you plan to have underfloor air distribution in a data center environment your mechanical engineer should be able to tell you how much floor height you need for effective airflow. 8 lateral displacement energy absorbers designed to 6 2 richter as standard stronger design upon request design totally metallic according data centers fire protection standards. Why raised floor systems remain the industry standard in data centers during the design of data centers professionals often face the question of raised floor systems versus the use of an overhead cable tray while designing cabling distribution and air handling systems.
When used as an exhaust space refer to vdi 2054 for the floor room air conditioning system standard for floor height. It is also probable that you will have a fairly low raised floor assuming you re using under floor air distribution. If the data center is small as well you ll also have rather uneven air flow. Your first time choice our life time service.
Application type data center office medical facility industrial site etc cooling system air distribution setup. Raised floors are widely used in modern office buildings and in specialized areas such as command centers information technology data. Depending on data center size and the amount of equipment that needs to be cooled a raised floor in today s world should be at least 18 inches high preferably 24 30 inches to hold the necessary cable bundles without impeding the high volumes of air flow needed to cool modern technology. Traditional standard access floor post and panel raised floor low profile access floor cable management floor the type of raised floor needed depends upon several considerations.
The raised floor is constructed of 600x600mm anti static floor tiles to the information room with a height of at least 300mm.